Indirect Cooler
Wet bulb temperature: depends on where the product is used
Electricity conditions: about 380V 50Hz
Connection piping: generally use PPR piping ring arrangement
Shower water control: automatic control of water replenishment and closure by stainless steel float valves in the tank
Transmission form: the fan form for the direct-connected fully enclosed airflow type, maintenance-free
Heat exchanger structure: serpentine coil
Coil design pressure: not less than 1.0MPa, with Corrosion resistance
High-efficiency inlet grille: good thermal performance and resistance characteristics, oxygen index ≥ 44.5
Product Brand: LZBF
Products Description
Indirect cooler, using the evaporation of the spray water, brought out by the air outside the indirect cooler, to cool the circulating medium in the heat exchange tubes, the circulating medium and the outside world is completely isolated.
As the spray water vaporisation, a large number of water vapour and air mixing, humidity increases, the need for strong extraction equipment, that is, fans, these saturated, high humidity, high enthalpy air out of indirect cooler outside. On the surface, it seems that the air is cooled, and at the same time there is evaporation of spray water, referred to as indirect cooler, sometimes also known as evaporative cooler.

Principle of work
Latent heat of vaporization: indirect cooler and closed cooling tower is basically the same, relying on the evaporation of the spray water outside the heat transfer tube, absorbing the latent heat of vaporization, take away indirect cooler closed heat transfer tube in the industrial circulating water medium heat energy;
Between the wall of the heat transfer: indirect cooler of the spray water and air, and the circulating medium is completely isolated, without any contact, indirect cooler. Any contact, indirect cooler only heat transfer, no contact.

Main Advantages
No evaporation: indirect cooler only cools down, no evaporation, no consumption, the circulating medium is completely isolated from the outside air, without any contact, no medium evaporation consumption and impurities into the indirect cooler can ensure the stability of the internal medium composition.
No scaling: because there is no evaporation, the media scale ions such as calcium, magnesium, sulfate and other concentrations do not change, so there will be no scaling.
Convenient maintenance: indirect cooler coils are all visible, maintenance is convenient, easy to overhaul.
Hot Tags: indirect cooler, China indirect cooler manufacturers, suppliers, factory, Closed Loop Cooling Tower System, Indirect Air Cooler, Closed Circuit Evaporative Cooling Tower, Indirect Cooler, Indirect Evaporative Air Cooler, Indirect Direct Evaporative Cooling Unit
You Might Also Like