Compound Cross Type Closed Cooling Towers
Definition: a device that can cool water
Float valve: SUS304 stainless steel, long service life, good water replenishment
Air intake classification: single-side air intake and two-side air intake
Product features: easy transport and installation, excellent heat exchange performance
Fan structure: direct-connected structure without transmission loss
Fan type: axial flow, centrifugal, generally axial flow
Similar equipment: Counter-flow cooling tower, composite flow cooling tower, etc.
Noise Level: Ordinary type P/Low noise type D/Extra-low noise type C/Industrial type G
Products Description
Compound cross type closed cooling towers can be assembled together side by side, and compared with counterflow cooling towers, it has a smaller area, therefore, Compound cross type closed cooling towers are more suitable for manufacturers with high noise requirement and smaller area.

Heat exchange coil Compound cross type closed cooling towers adopt multi-group coil structure, multi-group coils are installed in the air intake surface at both ends of Compound cross type closed cooling towers, and the coils are staggered with heat exchange packing design. The spray water passes through the coil of Compound cross type closed cooling towers and is cooled by the heat exchanger packing, and then flows into the bottom water collecting tray after repeated times.The heat exchanger coil of Compound cross type closed cooling towers is generally made of copper, and the heat exchanger packing can also be used in Compound cross type closed cooling towers under special circumstances. Compound cross type closed cooling towers can also be made of stainless steel, etc. After welding, Compound cross type closed cooling towers need to be pressurised so that there is no leakage or any sand holes. The test pressure of Compound cross type closed cooling towers is generally to put the heat exchanger coil into the water, and then inject high pressure air into the heat exchanger coil, and the air pressure is generally 20MPa.

All iron parts of Compound cross type closed cooling towers are hot dip galvanised, which improves the resistance of Compound cross type closed cooling towers under the circulating condition. All iron parts of Compound cross type closed cooling towers are hot dipped galvanised, which improves the corrosion and rust resistance of Compound cross type closed cooling towers under circulating conditions, resulting in a longer and more stable service life.
Hot Tags: compound cross type closed cooling towers, China compound cross type closed cooling towers manufacturers, suppliers, factory, Closed Loop Circuit Cooling Tower, Basic Closed Circuit Water Cooler, Closed Circuit Water Cooling System, Composite Closed Type Cooling Tower, Closed Circuit Fluid Cooler, Composite Flow Closed Cooling Tower
You Might Also Like
Send Inquiry